ESTIMATION OF THE CENTER OF MASS AND PELVIS MOVEMENT IN RUNNING USING AN INERTIA SENSOR MOUNTED ON SACRUM
Vol: 35, Issue: 1
2017
- 754Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage754
- Downloads653
- Abstract Views101
Paper Description
The purpose of this study was to compare the center of mass and pelvis movement measured by the inertia sensor, motion capture, and ground reaction force during running. Linear movements of the center of mass and pelvis rotation were measured by motion capture system and the inertia sensor mounted on sacrum for thirteen distance runners. Vertical movement of the sensor was well coincident with the center of mass but lateral and forward/backward movements were overestimated by the sensor. The forward tilt, tangular displacement and velocity of pelvis in a running cycle were almost same in the values by motion capture and sensor with some variances by the mounted position. It would be suggested that the inertia sensor is useful to evaluate the distance running motion with filtering and modification of offset and parameter relationship for individual.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know